Mostrar el registro sencillo del ítem
Experimental Assessment of Derating Guidelines Applied to Power Electronics Converters.
dc.contributor.author | DE LEON ALDACO, SUSANA ESTEFANY | |
dc.contributor.author | CALLEJA GJUMLICH, JORGE HUGO | |
dc.contributor.author | JIMENEZ GRAJALES, HUMBERTO RAUL | |
dc.contributor.author | CHAN PUC, FREDDY IGNACIO | |
dc.date.accessioned | 2018-09-14T21:35:17Z | |
dc.date.available | 2018-09-14T21:35:17Z | |
dc.date.issued | 2013 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12249/1405 | |
dc.description.abstract | "Power transistors are the most vulnerable components in switching converters, and derating is usually applied to increase their reliability. In this paper, the effectiveness of derating guidelines is experimentally assessed using a push-pull DC-DC converter as a case study, operating in three different environments. After measuring the electrical variables and temperature, reliability was predicted following the guidelines in MIL HDBK 217F. The sensitivity analysis performed indicates that temperature has the largest impact on reliability, followed by environment and device quality. The results obtained demonstrate that a derating procedure based solely on DC ratings does not ensure an adequate performance. Therefore, additional guidelines are suggested to help increase the overall reliability obtained from a power circuit." | |
dc.description.provenance | Submitted by Yaremi Isabel Can Chulin (1315421@uqroo.mx) on 2018-09-14T21:35:17Z No. of bitstreams: 1 DeLeon Aldaco-SE_Experimental-assessment-of-derating-guidelines-applied-to-power-electronics-converters.pdf: 566023 bytes, checksum: 9a4fb506f6cc0f8f34d099b3cb1f3946 (MD5) | |
dc.description.provenance | Made available in DSpace on 2018-09-14T21:35:17Z (GMT). No. of bitstreams: 1 DeLeon Aldaco-SE_Experimental-assessment-of-derating-guidelines-applied-to-power-electronics-converters.pdf: 566023 bytes, checksum: 9a4fb506f6cc0f8f34d099b3cb1f3946 (MD5) Previous issue date: 2013 | |
dc.format | ||
dc.language.iso | eng | |
dc.publisher | frty | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0 | |
dc.source | Journal of Applied Research and Technology | |
dc.subject | Reliability | |
dc.subject | Derating | |
dc.subject | Power Converters | |
dc.subject.classification | INGENIERÍA Y TECNOLOGÍA::CIENCIAS TECNOLÓGICAS | |
dc.title | Experimental Assessment of Derating Guidelines Applied to Power Electronics Converters. | |
dc.type | Artículo | |
dc.type.conacyt | article | |
dc.rights.acces | openAccess | |
dc.identificator | 7||33 | |
dc.audience | generalPublic | |
dc.identifier.doi | 10.1016/S1665-6423(13)71519-0 | |
dc.division | Biblioteca Unidad Académica Chetumal, Santiago Pacheco Cruz |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Artículos [192]